Natch S Pro Fully Automated Nucleic Acid Process System
Extraction InstrumentsWorkflow
Features
Integrated all-in-one platform for seamless workflow The unified system integrates sample preparation, nucleic acid extraction, and subsequent processing in a single device, eliminating manual transfers and minimizing cross-contamination risks. 1. CO-RE technology for precise pipettingUnique Compression-induced O-Ring Expansion (CO-RE) technology ensures precise tip at attachment and positioning. A low temperature module is equipped to prevent the reduction of enzyme activity The waste liquid channel is designed to work separately from the workstation, ensuring the cleanliness of the laboratory table Full board extraction time is reduced to 2hours Detection efficiency increased to 3.5h to complete 96 tests Interface operation is simplified, and the whole process of nucleic acid extraction can be automatically completed with one click Specifications
Instrument Model S-S14D Sample Type Serum, plasma, Whole blood Technology Platforms Advanced magnetic beads technology Sample Throughput 576 tests/batch Detection Time Pooling test: 576 tests/4.5 hours; Individual test: 96 tests/3.5 hours Sample Tube Spec. Compatible with original sample tubes of all sizes Pipetting Range 0.5-1000μL Pipetting Performance Pipetting volume 10μL, CV≤5%; 100μL, CV≤2%; 1000μL, CV≤1.5% Pipetting Channel 8 independent channels, with dual liquid level detection, clot detection, air tightness detection, tip detection, dynamic positioning and other functions. Liquid Level Detection Dual detection technology of pressure and capacitance can identify and record abnormal suction and discharge process (empty suction, missing suction, less suction, clot blockage) Extraction Principle Pipetting, side magnetism Magnetic Field Control Permanent magnet mode, three-dimensional surround magnetic attraction technology Tips Loading and Uploading CO-RE technology automatic tip loading and uploading Temperature Control Range Low temperature module: 0-15℃ adjustable Heating module: 5-105℃ adjustable Anti-contamination System UV lamp function, independent waste liquid channel Barcode Scanning Sample automatic scanning and sampling system (supports multiple barcodes), scanning time ≤ 1s Software System Window 7, Window 10 (recommended) Interface Type USB interface, RS232C serial port, support LIS system Operating Environment Temperature: 15-30 ℃ Humidity: 15%-85% (indoor, no condensation) Weight and Size About 220Kg, 2619mm(L)*903mm(H)*1043.5mm(W) Power Supply Voltage: 115VAC/230VAC, ±10% Frequency: 50/60Hz Certification NMPA -
Natch S Pro Fully Automated Nucleic Acid Extraction System
Extraction InstrumentsWorkflow
Features
1. CO-RE technology for precise pipettingUnique Compression-induced O-Ring Expansion (CO-RE) technology ensures precise tip at attachment and positioning. A low temperature module is equipped to prevent the reduction of enzyme activity The waste liquid channel is designed to work separately from the workstation, ensuring the cleanliness of the laboratory table Full board extraction time is reduced to 2hours Detection efficiency increased to 3.5h to complete 96 tests Interface operation is simplified, and the whole process of nucleic acid extraction can be automatically completed with one click Specifications
Instrument Model S-S14A Sample Type Serum, plasma Technology Platforms Advanced magnetic beads technology Sample Throughput 576 tests/batch (pooling test); 96 tests/batch (individual test) Extraction Time 576 tests ≤ 3 hours; 96 tests ≤ 2.5 hours Sample Tube Spec. Compatible with original sample tubes of all sizes Pipetting Range 0.5-1000μL Pipetting Performance Pipetting volume 10μL, CV≤5%; 100μL, CV≤2%; 1000μL, CV≤1.5% Pipetting Channel 8 independent channels, with dual liquid level detection, clot detection, air tightness detection, tip detection, dynamic positioning and other functions. Liquid Level Detection Dual detection technology of pressure and capacitance can identify and record abnormal suction and discharge process (empty suction, missing suction, less suction, clot blockage) Extraction Principle Pipetting, side magnetism Magnetic Field Control Permanent magnet mode, three-dimensional surround magnetic attraction technology Tips Loading and Uploading CO-RE technology automatic tip loading and uploading Temperature Control Range Low temperature module: 0-15℃ adjustable Heating module: 5-105℃ adjustable Anti-contamination System UV lamp function, independent waste liquid channel Barcode Scanning Sample automatic scanning and sampling system (supports multiple barcodes), scanning time ≤ 1s Software System Window 7, Window 10 (recommended) Interface Type USB interface, RS232C serial port, support LIS system Operating Environment Temperature: 15-30 ℃ Humidity: 15%-85% (indoor, no condensation) Weight and Size About 150Kg, 1664mm(L)*903mm(H)*795mm(W) Power Supply Voltage: 115VAC/230VAC, ±10% Frequency: 50/60Hz Certification CE, NMPA -
Natch 16S Nucleic Acid Extraction System
Extraction InstrumentsSpecifications
ModelNatch 16SSample throughput1-16Extraction technology Magnetic bead technologyPurification differences between wellsCV≤5%Mixing modeTip comb moving up and down to mix, 10 different mixing modesExtraction time10-60 minutes/batchAnti-contaminationBuilt-in UV lamp and air filtration systemOperation modeTouch controlProgram managementCreate, copy, delete, import, export and editDisplay7-inch touch screenInterfaceUSBPower supplyInput: AC 100V-240V, 50-60Hz, 120VASize≤200mm×300mm×300mm (L×D×H) Net weight≤8Kg Extraction kit components
No. Spec. Product Name S10016E 48T/kit Nucleic Acid Extraction-Purification Kit (Magnetic beads method) Available projects
Sexually Transmitted Diseases : CT, NG, UU, HSV-2, HSV I/2 Women's Health : hrHPV and hrHPV genotyping Respiratory Tract Disease : 6RP, TB, MP, RSV, ADV, BP Gastrointestinal Diseases : HFMD Prenatal and Postnatal care : CMV, EBV Public Health : SARS-CoV-2, Influenza A/B, HINI, H7N9 Customerized Projects -
Natch 48 Nucleic Acid Extraction System
Extraction InstrumentsExtremely simple workflow
Specifications
Instrument model Natch 24/48/96 Sample type Serum, plasma, whole blood, secretions, exfoliated cells, tisues, throat swabs, anal swabs, urine, feces, etc. Extraction technology Advanced magnetic beads technology Sample type Volume 1-96 tests/batch Extraction Time 10-60 minutes each batch Working volume 30-2000uL Recovery rate of magnetic beads >95% Blending mode Vortex omnidirectional liquid mixing Temperature control range Adjustable from roomtemperature to 125℃ Operation 7-inch touch screen Storage Up to 120 groups of programs can be used. Size and weight 655x655x520 mm (L x W x H), weight: 65kg Qualification CE Extraction kit components
No. Spec. Product Name S10016E 48T/kit Nucleic Acid Extraction-Purification Kit (Magnetic beads method) Available projects
Sexually Transmitted Diseases : CT, NG, UU, HSV-2, HSV I/2 Women's Health : hrHPV and hrHPV genotyping Respiratory Tract Disease : 6RP, TB, MP, RSV, ADV, BP Gastrointestinal Diseases : HFMD Prenatal and Postnatal care : CMV, EBV Public Health : SARS-CoV-2, Influenza A/B, HINI, H7N9 Customerized Projects -
Natch CS2 Fully Automated Nucleic Acid Extraction System
Extraction InstrumentsExtremely simple workflow
Features
1. Efficient anti-contamination- Well-organized countertop layout
- Sample area is separated from clean area
- Effective UV decontamination
- Anti-contanmination function of moving path
- Super 3-D magnetic adhesion technology
- Permanent magnetic mode
- 117 magnetic racks, 4 magnetic bars in each well
- Automatic liquid level detection
- Clot detection
- Tip detection
- Air-prof detection
- Preset programs, one-key selection
- Prompt the placement of reagents
- Display the status of reagents and consumables
- Real-time display of remaining time
- Show real-time experimental procedures
- Permits LIS compatibility
Specifications
Instrument model S-S13A Sample type Serum, plasma, whole blood, secretions, exfoliated cells, tissues, nasopharyngeal swab, oropharyngeal swab, urine, feces, etc. Sample tube specifications Compatible with various original sample tubes Extraction Principle one-tube fast release technology (OT) Advanced magnetic beads technology (MB) Sample type Volume OT: 1-96 tests/batch; MB: 1-96 tests/batch Extraction Time OT of 96 tests ≤ 30 minutes; MB of 96 tests ≤ 90 minutes Pipetting range 10~1000 μL Level detection Pressure detection / capacitance detection, automatic detection of liquid level Clot detection Pressure detection, automatic detection of liquid aspiration and liquid clogging Sample loading function Automatic liquid level detection Clot detection Tips detection Air-prof detection Magnetic field control Permanent magnet mode Patented design Super 3-D magnetic adhesion technology Blending mode Vortex omnidirectional liquid mixing Temperature control range Adjustable from room temperature to 100℃ UV disinfection Timed opening and closing Barcode Scanning Sample scanning system Supported multiple barcodes Language Simplified Chinese / English Display Method 10.4 inches touch screen Communication Interface USB, RS232, network ports, HDMI Dimensions and Weight 1320×850×1600mm (LxWxH), weight: 350Kg Power supply Input: AC 100-240V 50/60Hz 350 VA Qualification CE Extraction kit components
No. Spec. Product Name S1013E 48T/kit Sample Release Reagent S1014E 24T/Kit, 48T/kit Sample Release Reagent S1002E 24T/kit Nucleic Acid (DNA/RNA) Extraction or Purification Kit (Magnetic beads method) S1006E 48T/kit Multi-type Sample DNA/RNA Extraction-Purification Kit (Magnetic beads method) S10016E 48T/kit Nucleic Acid Extraction-Purification Kit (Magnetic beads method) Available projects
Hepatitis and AIDS : HBV, HCV, HIV Sexually Transmitted Diseases : CT, NG, UU, HSV-2, HSV I/2 Women's Health : hrHPV and hrHPV genotyping Respiratory Tract Disease : 6RP, TB, MP, RSV, ADV, BP Gastrointestinal Diseases : HFMD Prenatal and Postnatal care : CMV, EBV Public Health : SARS-CoV-2, Influenza A/B, HINI, H7N9 Customerized Projects