  • Natch S Pro Fully Automated Nucleic Acid Process System

    Workflow

    Features

    Integrated all-in-one platform for seamless workflow The unified system integrates sample preparation, nucleic acid extraction, and subsequent processing in a single device, eliminating manual transfers and minimizing cross-contamination risks. 1. CO-RE technology for precise pipetting
    Unique Compression-induced O-Ring Expansion (CO-RE) technology ensures precise tip at attachment and positioning.
    2. Low temperature preservation module to ensure enzymatic activity 
    A low temperature module is equipped to prevent the reduction of enzyme activity
    3. Independent waste liquid channel to prevent countertop contamination 
    The waste liquid channel is designed to work separately from the workstation, ensuring the cleanliness of the laboratory table
    4. 96 HEAD, Greatly shorten nucleic acid extraction time
    Full board extraction time is reduced to 2hours Detection efficiency increased to 3.5h to complete 96 tests
    5. One-click automatic operation, no need to be on duty throughout the process
    Interface operation is simplified, and the whole process of nucleic acid extraction can be automatically completed with one click

    Specifications

    Instrument Model S-S14D
    Sample Type Serum, plasma, Whole blood
    Technology Platforms Advanced magnetic beads technology
    Sample Throughput 576 tests/batch
    Detection Time Pooling test: 576 tests/4.5 hours;  Individual test: 96 tests/3.5 hours
    Sample Tube Spec. Compatible with original sample tubes of all sizes
    Pipetting Range 0.5-1000μL
    Pipetting Performance Pipetting volume 10μL, CV≤5%; 100μL, CV≤2%; 1000μL, CV≤1.5%
    Pipetting Channel 8 independent channels, with dual liquid level detection, clot detection, air tightness detection, tip detection, dynamic positioning and other functions.
    Liquid Level Detection Dual detection technology of pressure and capacitance can identify and record abnormal suction and discharge process (empty suction, missing suction, less suction, clot blockage)
    Extraction Principle Pipetting, side magnetism
    Magnetic Field Control Permanent magnet mode, three-dimensional surround magnetic attraction technology
    Tips Loading and Uploading CO-RE technology automatic tip loading and uploading
    Temperature Control Range Low temperature module: 0-15℃ adjustable Heating module: 5-105℃ adjustable
    Anti-contamination System UV lamp function, independent waste liquid channel
    Barcode Scanning Sample automatic scanning and sampling system (supports multiple barcodes), scanning time ≤ 1s
    Software System Window 7, Window 10 (recommended)
    Interface Type USB interface, RS232C serial port, support LIS system
    Operating Environment Temperature: 15-30 ℃ Humidity: 15%-85% (indoor, no condensation)
    Weight and Size About 220Kg, 2619mm(L)*903mm(H)*1043.5mm(W)
    Power Supply Voltage: 115VAC/230VAC, ±10% Frequency: 50/60Hz
    Certification NMPA
     
  • Natch S Pro Fully Automated Nucleic Acid Extraction System

    Workflow

    Features

    1. CO-RE technology for precise pipetting
    Unique Compression-induced O-Ring Expansion (CO-RE) technology ensures precise tip at attachment and positioning.
    2. Low temperature preservation module to ensure enzymatic activity 
    A low temperature module is equipped to prevent the reduction of enzyme activity
    3. Independent waste liquid channel to prevent countertop contamination 
    The waste liquid channel is designed to work separately from the workstation, ensuring the cleanliness of the laboratory table
    4. 96 HEAD, Greatly shorten nucleic acid extraction time
    Full board extraction time is reduced to 2hours Detection efficiency increased to 3.5h to complete 96 tests
    5. One-click automatic operation, no need to be on duty throughout the process
    Interface operation is simplified, and the whole process of nucleic acid extraction can be automatically completed with one click

    Specifications

    Instrument Model S-S14A
    Sample Type Serum, plasma
    Technology Platforms Advanced magnetic beads technology
    Sample Throughput 576 tests/batch (pooling test); 96 tests/batch (individual test)
    Extraction Time 576 tests ≤ 3 hours; 96 tests ≤ 2.5 hours
    Sample Tube Spec. Compatible with original sample tubes of all sizes
    Pipetting Range 0.5-1000μL
    Pipetting Performance Pipetting volume 10μL, CV≤5%; 100μL, CV≤2%; 1000μL, CV≤1.5%
    Pipetting Channel 8 independent channels, with dual liquid level detection, clot detection, air tightness detection, tip detection, dynamic positioning and other functions.
    Liquid Level Detection Dual detection technology of pressure and capacitance can identify and record abnormal suction and discharge process (empty suction, missing suction, less suction, clot blockage)
    Extraction Principle Pipetting, side magnetism
    Magnetic Field Control Permanent magnet mode, three-dimensional surround magnetic attraction technology
    Tips Loading and Uploading CO-RE technology automatic tip loading and uploading
    Temperature Control Range Low temperature module: 0-15℃ adjustable Heating module: 5-105℃ adjustable
    Anti-contamination System UV lamp function, independent waste liquid channel
    Barcode Scanning Sample automatic scanning and sampling system (supports multiple barcodes), scanning time ≤ 1s
    Software System Window 7, Window 10 (recommended)
    Interface Type USB interface, RS232C serial port, support LIS system
    Operating Environment Temperature: 15-30 ℃ Humidity: 15%-85% (indoor, no condensation)
    Weight and Size About 150Kg, 1664mm(L)*903mm(H)*795mm(W)
    Power Supply Voltage: 115VAC/230VAC, ±10% Frequency: 50/60Hz
    Certification CE, NMPA
     
  • Natch 16S Nucleic Acid Extraction System

    Specifications

    Model
    Natch 16S
    Sample throughput
    1-16
    Extraction technology
    Magnetic bead technology
    Purification differences between wells
    CV5%
    Mixing mode
    Tip comb moving up and down to mix, 10 different mixing modes
    Extraction time
    10-60 minutes/batch
    Anti-contamination
    Built-in UV lamp and air filtration system
    Operation mode
    Touch control
    Program management
    Create, copy, delete, import, export and edit
    Display
    7-inch touch screen
    Interface
    USB
    Power supply
    Input: AC 100V-240V, 50-60Hz, 120VA
    Size
    200mm×300mm×300mm (L×D×H)
    Net weight
    8Kg

    Extraction kit components

    No. Spec. Product Name
    S10016E 48T/kit Nucleic Acid Extraction-Purification Kit (Magnetic beads method)

    Available projects

    Sexually Transmitted Diseases : CT, NG, UU, HSV-2, HSV I/2 Women's Health : hrHPV and hrHPV genotyping Respiratory Tract Disease : 6RP, TB, MP, RSV, ADV, BP Gastrointestinal Diseases : HFMD Prenatal and Postnatal care : CMV, EBV Public Health : SARS-CoV-2, Influenza A/B, HINI, H7N9 Customerized Projects
  • Natch 48 Nucleic Acid Extraction System

    Extremely simple workflow

    Specifications

    Instrument model Natch 24/48/96
    Sample type Serum, plasma, whole blood, secretions, exfoliated cells, tisues, throat swabs, anal swabs, urine, feces, etc.
    Extraction technology Advanced magnetic beads technology
    Sample type Volume 1-96 tests/batch
    Extraction Time 10-60 minutes each batch
    Working volume 30-2000uL
    Recovery rate of magnetic beads >95%
    Blending mode Vortex omnidirectional liquid mixing
    Temperature control range Adjustable from roomtemperature to 125℃
    Operation 7-inch touch screen
    Storage Up to 120 groups of programs can be used.
    Size and weight 655x655x520 mm (L x W x H), weight: 65kg
    Qualification CE

    Extraction kit components

    No. Spec. Product Name
    S10016E 48T/kit Nucleic Acid Extraction-Purification Kit (Magnetic beads method)

    Available projects

    Sexually Transmitted Diseases : CT, NG, UU, HSV-2, HSV I/2 Women's Health : hrHPV and hrHPV genotyping Respiratory Tract Disease : 6RP, TB, MP, RSV, ADV, BP Gastrointestinal Diseases : HFMD Prenatal and Postnatal care : CMV, EBV Public Health : SARS-CoV-2, Influenza A/B, HINI, H7N9 Customerized Projects
  • Natch CS2 Fully Automated Nucleic Acid Extraction System

    Extremely simple workflow

    Features

    1. Efficient anti-contamination
    • Well-organized countertop layout
    • Sample area is separated from clean area
    • Effective UV decontamination
    • Anti-contanmination function of moving path
    2. Super magnetic, effective adsorption
    • Super 3-D magnetic adhesion technology
    • Permanent magnetic mode
    • 117 magnetic racks, 4 magnetic bars in each well
    3. Excellent sample addition function
    • Automatic liquid level detection
    • Clot detection
    • Tip detection
    • Air-prof detection
    4. Easy-to-use software
    • Preset programs, one-key selection
    • Prompt the placement of reagents
    • Display the status of reagents and consumables
    • Real-time display of remaining time
    • Show real-time experimental procedures
    • Permits LIS compatibility

    Specifications

    Instrument model S-S13A
    Sample type Serum, plasma, whole blood, secretions, exfoliated cells, tissues, nasopharyngeal swab, oropharyngeal swab, urine, feces, etc.
    Sample tube specifications Compatible with various original sample tubes
    Extraction Principle one-tube fast release technology (OT) Advanced magnetic beads technology (MB)
    Sample type Volume OT: 1-96 tests/batch; MB: 1-96 tests/batch
    Extraction Time OT of 96 tests ≤ 30 minutes; MB of 96 tests ≤ 90 minutes
    Pipetting range 10~1000 μL
    Level detection Pressure detection / capacitance detection, automatic detection of liquid level
    Clot detection Pressure detection, automatic detection of liquid aspiration and liquid clogging
    Sample loading function Automatic liquid level detection Clot detection Tips detection Air-prof detection
    Magnetic field control Permanent magnet mode Patented design Super 3-D magnetic adhesion technology
    Blending mode Vortex omnidirectional liquid mixing
    Temperature control range Adjustable from room temperature to 100℃
    UV disinfection Timed opening and closing
    Barcode Scanning Sample scanning system Supported multiple barcodes
    Language Simplified Chinese / English
    Display Method 10.4 inches touch screen
    Communication Interface USB, RS232, network ports, HDMI
    Dimensions and Weight 1320×850×1600mm (LxWxH), weight: 350Kg
    Power supply Input: AC 100-240V 50/60Hz 350 VA
    Qualification CE

    Extraction kit components

    No. Spec. Product Name
    S1013E 48T/kit Sample Release Reagent
    S1014E 24T/Kit, 48T/kit Sample Release Reagent
    S1002E 24T/kit Nucleic Acid (DNA/RNA) Extraction or Purification Kit (Magnetic beads method)
    S1006E 48T/kit Multi-type Sample DNA/RNA Extraction-Purification Kit (Magnetic beads method)
    S10016E 48T/kit Nucleic Acid Extraction-Purification Kit (Magnetic beads method)

    Available projects

    Hepatitis and AIDS : HBV, HCV, HIV Sexually Transmitted Diseases : CT, NG, UU, HSV-2, HSV I/2 Women's Health : hrHPV and hrHPV genotyping Respiratory Tract Disease : 6RP, TB, MP, RSV, ADV, BP Gastrointestinal Diseases : HFMD Prenatal and Postnatal care : CMV, EBV Public Health : SARS-CoV-2, Influenza A/B, HINI, H7N9 Customerized Projects
×
Get in touch with us
I confirm that I have reviewed Sansure's Privacy Policy and agree with the collection and storage of my personal data.
SUBMIT

Thank you!

We shall contact you soon!
Back Top