SLAN – 96H Real-Time PCR Instrument
Brief
SLAN-96H, the avant-garde leader in real-time fluorescent quantitative PCR analysis, is designed for on-the-go testing, simplifying even the most complex procedures into effortless tasks. With a sleek and portable design that fits easily into a backpack, it empowers molecular detection to be conducted with unmatched ease and precision. This technology elevates the testing experience to a new level of convenience and efficiency.
Revolutionary temperature control technology
1. Amplification takes only 30 minutes, approximately half the time of conventional PCR instruments.
2. It enables the rapid and accurate detection of gene expression variations as minimal as 2-fold.
Smart Portable Design
1. Weighing under 10 kg, the instrument is one-third the weight of conventional thermal cyclers and can be carried in a backpack for molecular detection.
2. The instrument is operational without calibration after relocation.
Interoperable Open Platform
Compatible with various reagents, the device allows for customized experiments.
Eight-color fluorescence detection system
Detects up to 8 targets per well, enhancing efficiency.
Robust Software System
The software offers various analysis modes, including qualitative/absolute quantification, melt curve analysis, endpoint genotyping, HRM analysis, isothermal amplification, etc.
Specifications
Performance
Sample Capacity
|
96 wells (1×96-well×0.2 mL)
|
Consumables
|
0.2mL PCR tubes, 8-tube strip
|
Light Source
|
High power LED (Maintenance-free)
|
Detector
|
High sensitivity photoelectric sensor
|
Dynamic Range
|
100 – 1010
|
Sensitivity
|
1 copy
|
Quantitative Repeatability
|
CV≤2.00%
|
Correlation
|
|r|≥0.9990
|
Concentration Differentiation
|
2-fold
|
Sample Volume
|
15μL – 100μL
|
Probe/Dye
|
Channel 1: FAM, SYBR-Green Channel 2:VIC, HEX, JOE, TET Channel 3: ROX, Texas-Red Channel 4: CY 5 Channel 5: QUASAR705, CY5.5 Channel 6: ATTO425 Channel 7: CY7 Channel 8: AF405 |
Thermal System
Control Mode
|
Temperature control mode
|
Temperature Indication Error
|
±0.1℃ |
Temperature Uniformity
|
±0.1℃ |
Temperature Control Range
|
4℃– 99℃
|
Avg Heating Rate
|
≥8℃/Sec
|
Max Heating Rate
|
≥10℃/Sec
|
Avg Cooling Rate
|
≥5℃/Sec
|
Max Cooling Rate
|
≥7℃/Sec
|
Hot-lid
|
Auto Hot-lid
(Adjustable range 30℃ – 120℃/default 105℃) |
Working Condition
Operating System
|
Windows 7/8/10/11
|
Software
|
Packaged project management
|
Power
|
850 W
|
Power Input
|
100 – 240 VAC, 50/60Hz
|
Size
|
208mm × 317mm × 243mm (W×D×H)
|
Weight
|
10kg
|
Interface
|
USB
|